Properties:
- Output of vibration velocity (RMS 10Hz–1kHz, 0 - 20 mm/s) according DIN/ISO 10816, 5199, 9905
- Condition monitoring up to 5.6 kHz (normal / unacceptable operation mode)
- 4 ... 20 mA interface
- Installation up to 160 °C surface temperature by use of cooling elements
- LED display green, yellow and red
- Digital communication through FSK* modem (HART® compatible) for further information and for use of the
SIHIvibrosoft Software**
- EDD for Siemens SIMATIC PDM and Emerson AMS**
- DTM driver for FDT frame applications (PACTware, FieldCare, SMART VISION, etc.)**
- Integrated error memory
- Simple mounting at the pump
- Requires no experience of vibration analysis technology
- Suitable for installation in hazardous areas (up to zone 1)
* FSK Frequency Shift Keying ** Optional extra
Technical data:
- Construction: | | Polyamide PA6, fibre - glass reinforced, protection class IP66 (EN 60529) |
- Connection: | | 2 x 2.5 mm² terminal block |
- Dimension: | | 79 mm x 42 mm x 53 mm |
- Ambiente temperature: | | - 40 °C to + 80 °C |
- Power loop: | | 4 ... 20 mA; 11 ... 30 VDC |
- Ex protection type (potional): | | Ex II 2G Ex ia IIC T4 - TÜV 07 ATEX 553845 |
Simple installation:
- Simple installation at the bearing bracket or volute casing. Sensor can also be bonded using a glue adapter. | | 
|
- Electrical connection | | 
|
- Simple calibration by pushing button | | 
|
Functions:
RMS vibration velocity Detection: - unbalance - misalignment - detrimental pipe work forces - etc. | | 
|
| | |
Condition monitoring Detection: - unacceptable operation mode for example cavitation, bearing wear, exceeding of max flow rate, etc. | | 
|
SIHIvibrosoft software:
Available as an optional extra, SIHIvibrosoft software has been developed purposely for professional analysis of the data, which has been generated by the SIHIdetect sensor. Detailed evaluation of the data can subsequently be made in order to reveal very specific aspects of vibration.
Condition monitoring - visualisation of vibration data - frequency-specific, and/or general, threshold magnitudes based on calibration data - data logging
Service - extracting the error memory - sensor temperature
Data analysis - evaluation data logging - trend analysis for wear - analysis of intermittent anomalies | | 
|